LVD, EMC or RED? Define the CE Scope from the Product Configuration

2026-08-17 SCS Testing Source: SCS Testing Technical Notes

LVD, EMC or RED? Define the CE Scope from the Product Configuration

“Our product runs on 12 V. Do we only need EMC?” “Can the Bluetooth version use the report for the standard model?” Neither question can be answered from a product name or an old report alone. First distinguish the finished product, external power supply and radio configuration, then identify the applicable legislation and evidence.

Three routes, different questions

RouteStart by checkingCommon misunderstanding
Low Voltage Directive (LVD)Rated voltage, product category and exclusions“Low voltage” covers every low-voltage electronic product
Electromagnetic Compatibility Directive (EMC)Emissions, immunity and intended environmentA safety result also establishes EMC compliance
Radio Equipment Directive (RED)Whether the product is radio equipment and which functions it hasA tested radio module automatically covers the finished product

Article 1 of LVD 2014/35/EU sets rated-voltage limits of 50–1000 V AC and 75–1500 V DC, subject to the exclusions in Annex II. For a 12 V device supplied by an external adapter, review the device and adapter separately. A 12 V label on the device does not, by itself, establish that the whole supplied arrangement needs no safety assessment.

EMC requirements address disturbance generated by equipment and its immunity in the intended environment. The test selection depends on the ports, use, installation environment and relevant standards; there is no single test list to copy onto every product.

Review the route again when radio functions are added

Where the product is radio equipment covered by RED, assess it under that framework. Article 3(1) of RED includes safety and EMC requirements; its safety objectives apply without the LVD voltage limit. Article 3(2) also addresses effective and efficient use of radio spectrum. Treating the process as a fixed bundle of three unrelated reports can miss the actual assessment needed.

Module documentation helps identify what has already been assessed and under which conditions. For integration into the product, also review the antenna, supply, software controls, enclosure and use distance. Record which evidence remains applicable and which differences need further assessment; a matching module number is not sufficient justification on its own.

What to send with an enquiry

  • Intended use, users and destination markets, including whether use is domestic, professional or in a fixed installation.
  • Finished-product input/output ratings, external adapter models and whether they are supplied together.
  • Radio technologies, bands, antenna arrangements, installation and software version.
  • Model-family differences and existing reports with the configurations they cover.

Use that information to agree the legislation, standard editions, representative samples and deliverables. CE marking does not mean every project requires a generic “CE certificate.” The Commission’s LVD guidance explains the manufacturer’s responsibility for conformity assessment.

Send product information through SCS’s electrical safety and LVD or EMC service pages. For radio configurations, include radio and RF exposure assessment in the discussion. A clear scope gives the quotation, samples and document review a common basis.

Sources checked on 21 October 2026. This overview is not an exhaustive list of product legislation or additional RED requirements.