A product comes in a basic, higher-power and wireless version. Can one sample support all three models? Do not select the highest-power version on that basis alone. A sales family name does not explain the technical relationship among circuits, construction, power supplies and operating modes. A representative sample for one test may not represent the family for another.
Turn “nearly identical” into recorded differences
Before requesting a quotation, prepare a model matrix covering enclosure and materials, PCB, ratings, adapter, critical components, radio module and antenna, software version and operating modes. If an item is identical, say so. If it differs, identify the actual part or parameter rather than describing everything as “basically the same”.
The following is a hypothetical example of record keeping, not a sample-selection decision for a real product:
| Model | Difference from the basic model | Information to explain |
|---|---|---|
| A | 30 W, no radio function | Baseline PCB, enclosure, supply and software versions |
| B | 60 W, different supply and cooling parts | Supply specification, cooling construction and material differences |
| C | 60 W, using B's power-supply and cooling configuration with an added radio module | Module and antenna types, positions, operating modes and software controls |
B's higher power deserves attention, but C's added radio function also needs assessment. The ratings alone do not establish that B represents A and C for every test.
Select the configuration for each assessment
Safety assessment may concern temperature, insulation, mechanical construction, critical materials and abnormal operation. For a product subject to the LVD, Annex III requires technical documentation to include risk analysis relevant to the applicable requirements. Sample selection needs to connect those risks with the differences among models.
An EMC project also considers ports, cables, supplies, loads and operating modes. Annex II of the EMC Directive calls for assessment of normal intended operating conditions and configurations identified by the manufacturer as representative of intended use. This does not mean an arbitrarily selected sample covers every model.
Differences in radio functions, antennas or transmitter settings require their own scope review. Some assessments may use different configurations of the same unit; others may need additional samples or tests. Agree quantities and combinations after review. Where a particular certification scheme defines family rules, those rules must also be followed.
Record the selection in the submission plan
- The full model list and the meaning of each suffix.
- The sample, accessories, software version and operating mode for each assessment.
- The technical reason for selecting that configuration and its relationship to the other models.
- Differences not yet covered, with the drawings, evidence or tests still required.
Tell the project contact if the supply, PCB, antenna or material changes during testing. Adding a model just before report issue leaves the underlying differences unresolved. Listing a model in a report does not replace the technical basis for its inclusion.
For a project enquiry, send SCS the model matrix, internal and external photographs, specifications, critical-component list and target-market requirements. Confirm the planned EMC, electrical-safety or radio scope before arranging samples. This gives the discussion a clear basis when additional models are proposed.
Public sources checked: 21 October 2026. The example and suggested workflow support preparation; the applicable standards, scheme rules and product assessment determine the actual approach.